  Datasheet File OCR Text:
 Current Transducer LTC 1000-S
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
1000 A
Electrical data
IPN IP IP RM Primary nominal r.m.s. current Primary current, measuring range @ 24 V Max overload not measurable Measuring resistance with 15 V with 24 V ISN KN VC IC @ 1000 A max @ 1200 A max @ 1000 A max @ 2000 A max 1000 A 0 .. 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7
Features
* Closed loop (compensated) current
transducer using the Hall effect
* Insulated plastic case recognized
according to UL 94-V0
* Railway equipment.
Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption
200 mA 1 : 5000 15 .. 24 V < 30 (@24V)+ IS mA
Advantages
* * * * * * *
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference * Current overload capability.
Accuracy - Dynamic performance data
XG Overall accuracy @ IPN , TA = 25C @ IPN , TA = - 40C .. + 85C Linearity error Offset current @ IP = 0, TA = 25C Thermal drift of IO - 40C .. + 85C Response time 2) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB) < 0.4 <1 < 0.1 Max 0.5 1 <1 > 100 DC .. 100 % % % mA mA s A/s kHz
L
IO IOT tr di/dt f
Applications
* AC variable speed drives and servo
motor drives
* Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies
(UPS)
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 85C Mass Standards - 40 .. + 85 C - 45 .. + 90 C 44 750 g EN 50155 : 2001
* Switched Mode Power Supplies
(SMPS)
* Power supplies for welding
applications.
Application Domain
* Traction
Notes :
1) 2)
With a di/dt of > 5 A/s With a di/dt of 100 A/s.
060615/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 1/4
LEM
w w w .lem.com
Current Transducer LTC 1000-S
Isolation characteristics
Vd Ve dCp dCl CTI Notes : R.m.s. voltage for AC isolation test, 50 Hz, 1 mn R.m.s. voltage for partial discharge extinction Creepage distance Clearance distance Comparative Tracking Index (Group I)
3) 4) 5)
13.4 3) 1.5 4) > 2.8 5) Min 66.70 45.90 600
kV kV kV mm mm
Between primary and secondary + shield Between secondary and shield Test carried out with a busbar 40 mm centred in the through-hole.
Safety
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions.
Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected.
060615/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/4
LEM
w w w .lem.com
Dimensions LTC 1000-S
Front view
(in mm. 1 mm = 0.0394 inch)
Left view
Connection
Top view Mechanical characteristics
* General tolerance * Fixing the transducer
Recommended fastening torque * Primary through-hole * Connection of secondary Recommended fastening torque 1 mm 4 holes 5.5 mm 4 screws M5 4 Nm or 2.95 Lb.-Ft. 42 mm M5 threaded studs 2.2 Nm or 1.62 Lb.-Ft. Faston 6.3 x 0.8 mm
Remarks
* IS is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed
100C.
* Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
* This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...), please contact us.
060615/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 3/4
LEM
w w w .lem.com
LTC 1000-S / Mechanical adaptation accessories
Lines Accessories 1 2 3 4 5 6 7 8 9 10 11 Busbar KIT * (busbar : 210 x 40 x 12 mm) Busbar KIT * (busbar : 185 x 40 x 8 mm) Busbar KIT * (busbar : 285 x 36 x 12 mm) Busbar KIT * (busbar : 260 x 36 x12 mm) Busbar KIT * (busbar : 195 x 36 x 10 mm) Busbar KIT * (busbar : 36 mm x 325 mm) Busbar KIT * (busbar : 185 x 40 x 10 mm) Busbar KIT * (busbar : 180 x 40 x 12 mm) Busbar Fastening Kit (M5 x 25) ** dedicated to busbars from lines 1 to 5 and lines 7, 8. Busbar Fastening Kit (M5 X 40)** dedicated to busbar from line 6 Feet fixing Kit ***
References 93.34.61.100.0 * 93.34.61.102.0 93.34.61.103.0 93.34.61.104.0 ** 93.34.61.105.0 93.34.61.106.0 *** 93.34.61.107.0 93.34.61.108.0 93.34.61.200.0 93.34.61.201.0 93.34.63.100.0
including all the necessary for its mounting such as screws, washers, nuts, 2 clamps, busbar. as with * but without the busbar. including screws and 2 feet.
R.m.s. voltage value for partial discharge extinction depends on the busbar. Refer to the datasheet of the corresponding product.
060615/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 4/4
LEM
w w w .lem.com


▲Up To Search▲   

 
Price & Availability of LTC1000-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X